TYVEK

Chemical Protection & Cleanroom Products

Hover over image to zoom
CATIIICAT III
T5T5
T6T6
1073EN 1073-2
1149EN 1149-5

Tyvek® 200 Easysafe

TSCHF5SWHDE

DuPont™ Tyvek® 200 Easysafe. Hooded coverall. Stitched external seams. Elasticated wrists, ankles and face. Elasticated waist (stitched-in). Zipper flap. White.

Full Part Number :

TSCHF5SWHDE

Fabric / Material :

Tyvek® 200

Design :

Hooded coverall with elastics

Seam :

Stitched (external), yellow

Color :

White

Sizes :

SM,MD,LG,XL,2X,3X

Quantity/Box :

100 per box, individually packed.

img1

DuPont™ Tyvek® 200 Easysafe. Hooded coverall available in white, sizes SM to 3X. Robust yet lightweight (<180g per garment). 2-piece hood. Elasticated face, wrists, waist and ankles.
Tyvek® 200 fabric is a new and unique optimised polyethylene nonwoven from DuPont. It is softer and with a more open structure than Tyvek® 500/600. It is therefore less protective than Tyvek® 500/Tyvek® 600, but offers adequate Type 5 and 6 barrier protection and remains both air and moisture vapour permeable.

  • Certified according to Regulation (EU) 2016/425
  • Chemical protective clothing, Category III, Type 5 and 6
  • EN 1073-2 (protection against radioactive contamination)
  • Antistatic treatment (EN 1149-1) - on outside
  • Stitched external seams in yellow for visual identification and differentiation

SIZES

Product Size Article Number Additional info
SM D14886039
MD D14886047
LG D14886050
XL D14886064
2X D14886075
3X D14886081

PHYSICAL PROPERTIES

Data relating to mechanical performance of the fabrics used in DuPont chemical protective clothing, listed for the selected garment according to the test methods and relevant European standard, if applicable. Such properties, including abrasion and flex-cracking resistance, tensile strength and puncture resistance can help in the assessment of protective performance.

Property Test Method Result EN
Abrasion Resistance 7 EN 530 Method 2 >10 cycles 1 of 6 1
Colour N/A White N/A
Flex Cracking Resistance 7 EN ISO 7854 Method B >40000 cycles 5 of 6 1
Puncture Resistance EN 863 >5 N 1 of 6 1
Surface Resistance at RH 25%, inside 7 EN 1149-1 No antistatic treatment N/A
Surface Resistance at RH 25%, outside 7 EN 1149-1 < 2,5 • 109 Ohm N/A
Tensile Strength (MD) DIN EN ISO 13934-1 >30 N 1 of 6 1
Tensile Strength (XD) DIN EN ISO 13934-1 >30 N 1 of 6 1
Trapezoidal Tear Resistance (MD) EN ISO 9073-4 >10 N 1 of 6 1
Trapezoidal Tear Resistance (XD) EN ISO 9073-4 >10 N 1 of 6 1
  •  According to EN 14325
  •  According to EN 14126
  •  According to EN 1073-2
  •  According to EN 14116
  •   According to EN 11612
  •  Front Tyvek ® / Back
  •  Based on test according to ASTM D-572
  •  See Instructions for Use for further information, limitations and warnings
  •  Larger than
  •  Smaller than
  •  Not Applicable
  •  Standard Deviation

GARMENT PERFORMANCE

Information relating to the protective performance of a garment according to European standards where applicable. Includes important characteristics such as protection against radioactive contamination, seam strength and shelf life. Inward leakage and resistance to penetration by liquids, according to the relevant Type classification, are also detailed.

Property Test Method Result EN
Nominal protection factor 7 EN 1073-2 >5 1 of 3 3
Seam Strength EN ISO 13935-2 >50 N 2 of 6 1
Type 5: Inward Leakage of Airborne Solid Particulates EN ISO 13982-2 Pass N/A
Type 6: Resistance to Penetration by Liquids (Low Level Spray Test) EN ISO 17491-4, Method A Pass N/A
  •  According to EN 14325
  •  According to EN 1073-2
  •   According to EN 11612
  •   According to EN 11611
  •  Front Tyvek ® / Back
  •  Based on test according to ASTM D-572
  •  See Instructions for Use for further information, limitations and warnings
  •  Based on the average of 10 suits, 3 activities, 3 probes
  •  Larger than
  •  Smaller than
  •  Not Applicable
  •  Based on lowest single value

PENETRATION AND REPELLENCY

A specific test method, EN ISO 6530, is used to measure the indexes of penetration, absorption and repellency of protective clothing material exposed to liquid chemicals. Results listed here reflect the penetration resistance and repellency of DuPont fabrics to 30% sulphuric acid and 10% sodium hydroxide.

Property Test Method Result EN
Repellency to Liquids, Sodium Hydroxide (10%) EN ISO 6530 >95 % 3 of 3 1
Repellency to Liquids, Sulphuric Acid (30%) EN ISO 6530 >90 % 2 of 3 1
Resistance to Penetration by Liquids, Sodium Hydroxide (10%) EN ISO 6530 <5 % 2 of 3 1
Resistance to Penetration by Liquids, Sulphuric Acid (30%) EN ISO 6530 <5 % 2 of 3 1
  •  According to EN 14325
  •  Larger than
  •  Smaller than

Warnings

  • The garment does not protect against ionizing radiation.
  • This garment and/or fabric are not flame resistant and should not be used around heat, open flame, sparks or in potentially flammable environments.
  • The information provided herein corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as new knowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated; these data may not be valid for such material used in combination with any other materials or additives or in any process, unless expressly indicated otherwise. The data provided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you may need to conduct to determine for yourself the suitability of a specific material for your particular purposes. Since DuPont cannot anticipate all variations in actual end-use conditions DuPont makes no warranties and assumes no liability in connection with any use of this information. Nothing in this publication is to be considered as a license to operate under or a recommendation to infringe any patent rights.