TYVEK

Chemical Protection & Cleanroom Products

Hover over image to zoom
0SOption 0S

Sierra™

Model ML7360 WH 0S

DuPont™ Sierra™ mask model ML 7360. Bound ties, metal nose piece. 23 cm. Gamma-sterilized. White.

Full Part Number :

ML7360WH0S

Fabric / Material :

Sierra™

Design :

Mask with rayon outer facing

Seam :

No seams

Color :

White

Sizes :

00

Quantity/Box :

250 per box, individually packed. Subgrouped by 50 in an outer bag. 2 polyethylene liners. Cardboard box.

DuPont™ Sierra™ mask, model ML 7360 WH 0S. Available in white and in one size. 23 cm. Gamma-sterilized.
Pleated rayon outer facing. Bound Tyvek® ties. Metal nose piece.
Sierra™ masks are typically used in cleanrooms within the biotech, pharmaceutical, medical device manufacturing, food processing, cosmetics industry as well as in other critical or controlled environments to provide process protection from human contamination.

  • Sterilized by gamma-irradiation to SAL of 10-6 (ISO 11137-1)
  • Suitable for use in GMP class C/D (ISO Class 6-9) clean rooms withor without Bioburden Control Areas
  • This accessory is not CE certified as chemical protective clothing

SIZES

Product Size Article Number Additional info
00 D13473980 One Size

PHYSICAL PROPERTIES

Data relating to mechanical performance of the fabrics used in DuPont chemical protective clothing, listed for the selected garment according to the test methods and relevant European standard, if applicable. Such properties, including abrasion and flex-cracking resistance, tensile strength and puncture resistance can help in the assessment of protective performance.

Property Test Method Result EN
Particle Filtration Efficiency (0.1 micron, not neutralized) ASTM F2299 92.0 % ± 2.5 % STD DEV N/A
  •  According to EN 14325
  •  According to EN 14126
  •  According to EN 1073-2
  •  According to EN 14116
  •   According to EN 11612
  •  Front Tyvek ® / Back
  •  Based on test according to ASTM D-572
  •  See Instructions for Use for further information, limitations and warnings
  •  Larger than
  •  Smaller than
  •  Not Applicable
  •  Standard Deviation

CLEANILESS

Particle Shedding (Helmke Drum) and Bacterial Filtration Efficiency Data

Property Test Method Result EN
Bacterial Filtration Efficiency (3 µm) ASTM F2101 96.0 % ± 1.4 % STD DEV N/A
  •  Front Tyvek ® / Back
  •  Larger than
  •  Smaller than
  •  Not Applicable
  •  Standard Deviation

Warnings

  • The intended use for Tyvek® IsoClean Accessories, that are not CE certified or certified as PPE Category I, does not include applications that may cause very serious consequences such as irreversible damage to health or death. The user should make the risk assessment to determine the protection required.
  • The information provided herein corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as new knowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated; these data may not be valid for such material used in combination with any other materials or additives or in any process, unless expressly indicated otherwise. The data provided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you may need to conduct to determine for yourself the suitability of a specific material for your particular purposes. Since DuPont cannot anticipate all variations in actual end-use conditions DuPont makes no warranties and assumes no liability in connection with any use of this information. Nothing in this publication is to be considered as a license to operate under or a recommendation to infringe any patent rights.