TYVEK

Chemical Protection & Cleanroom Products

Hover over image to zoom
CATIIICAT III
PB6PB[6]
14126EN 14126

Tyvek® IsoClean®

Model IC 729 S WH 0B

DuPont™ Tyvek® IsoClean® bouffant model IC 729S00. Not clean-processed and not sterilized. Serged seams. Elastic headband. White.

Full Part Number :

IC0729SWH00

Fabric / Material :

Tyvek® 500

Design :

Bouffant with elastic headband

Seam :

No seams

Color :

White

Sizes :

00

Quantity/Box :

250 per box, bulked packed. 2 polyethylene liners. Cardboard box.

DuPont™ Tyvek® IsoClean® bouffant, model IC729S00. Available in white and in one size. Not clean-processed and not sterilized. Elastic headband.
Tyvek® IsoClean® delivers an ideal balance of protection, durability and comfort. Made of high density polyethylene using a patented flash spinning process Tyvek® IsoClean® provides an inherent barrier to particles, microorganisms and non-hazardous light liquid splash.
Tyvek® IsoClean® (option codes 0B, 00 and BH) garments and accessories are neither clean-processed nor gamma-irradiated but manufactured in a controlled environment.
Garments and accessories made of Tyvek® IsoClean® are typically used in cleanrooms within the biotech, pharmaceutical, medical device manufacturing, food processing, cosmetics industry as well as in other critical or controlled environments.

  • Certified according to Regulation (EU) 2016/425
  • Partial body chemical protective clothing, Category III, Type PB [6-B]
  • EN 14126 (barrier to infective agents)
  • Suitable for use in GMP class C/D (ISO Class 6-9) clean rooms

SIZES

Product Size Article Number Additional info
00 D15531628 One Size

PHYSICAL PROPERTIES

Data relating to mechanical performance of the fabrics used in DuPont chemical protective clothing, listed for the selected garment according to the test methods and relevant European standard, if applicable. Such properties, including abrasion and flex-cracking resistance, tensile strength and puncture resistance can help in the assessment of protective performance.

Property Test Method Result EN
Abrasion Resistance 7 EN 530 Method 2 >100 cycles 2 of 6 1
Colour N/A White N/A
Flex Cracking Resistance 7 EN ISO 7854 Method B >100000 cycles 6 of 6 1
Puncture Resistance EN 863 >10 N 2 of 6 1
Tensile Strength (MD) DIN EN ISO 13934-1 >30 N 1 of 6 1
Tensile Strength (XD) DIN EN ISO 13934-1 >30 N 1 of 6 1
Trapezoidal Tear Resistance (MD) EN ISO 9073-4 >10 N 1 of 6 1
Trapezoidal Tear Resistance (XD) EN ISO 9073-4 >10 N 1 of 6 1
  •  According to EN 14325
  •  According to EN 14126
  •  According to EN 1073-2
  •  According to EN 14116
  •   According to EN 11612
  •  Front Tyvek ® / Back
  •  Based on test according to ASTM D-572
  •  See Instructions for Use for further information, limitations and warnings
  •  Larger than
  •  Smaller than
  •  Not Applicable
  •  Standard Deviation

GARMENT PERFORMANCE

Information relating to the protective performance of a garment according to European standards where applicable. Includes important characteristics such as protection against radioactive contamination, seam strength and shelf life. Inward leakage and resistance to penetration by liquids, according to the relevant Type classification, are also detailed.

Property Test Method Result EN
Seam Strength EN ISO 13935-2 >30 N 1 of 6 1
Seam Strength EN ISO 13935-2 >30 N 1 of 6 1
  •  According to EN 14325
  •  According to EN 1073-2
  •   According to EN 11612
  •   According to EN 11611
  •  Front Tyvek ® / Back
  •  Based on test according to ASTM D-572
  •  See Instructions for Use for further information, limitations and warnings
  •  Based on the average of 10 suits, 3 activities, 3 probes
  •  Larger than
  •  Smaller than
  •  Not Applicable
  •  Based on lowest single value

PERMEATION DATA

Permeation is the process by which a solid, liquid or gaseouses chemical moves through a protective clothing fabric at a molecular level. Permeation data assist in the selection of the most appropriate protective garment for a particular application and in the estimation of how long it can be safely worn. Standardised test methods are used to determine the resistance of DuPont materials to permeation, the results of which can be selected according to a specific chemical, chemical class or fabric.

Hazard / Chemical Name Physical State CAS BT Act BT 0.1 BT 1.0 EN SSPR MDPR Cum 480 Time 150 ISO
Acetic acid (30%) Liquid 64-19-7 imm imm imm 13.5 0.001
Ammonium hydroxide (16%) Liquid 1336-21-6 imm imm imm 20.3 0.005
Ammonium hydroxide (28% - 30%) Liquid 1336-21-6 imm imm imm 16.7 0.014
Carboplatin (10 mg/ml) Liquid 441575-94-4 >240 >240 >240 5 <0.001 0.001
Carmustine (3.3 mg/ml, 10 % Ethanol) Liquid 154-93-8 imm imm >240 5 <0.3 0.001
Caustic ammonia (16%) Liquid 1336-21-6 imm imm imm 20.3 0.005
Caustic ammonia (28% - 30%) Liquid 1336-21-6 imm imm imm 16.7 0.014
Caustic soda (10%) Liquid 1310-73-2 >240 >480 >480 6 <0.005 0.005
Caustic soda (40%) Liquid 1310-73-2 imm >30 >240 5 <0.005 0.005
Caustic soda (50%) Liquid 1310-73-2 imm >30 >240 6 0.85 0.01
Caustic soda (>95%, solid) Solid 1310-73-2 >480 >480 >480 6 <0.01 0.01
Cisplatin (1 mg/ml) Liquid 15663-27-1 >240 >240 >240 5 <0.0002 0.0002
Cyclo phosphamide (20 mg/ml) Liquid 50-18-0 >240 >240 >240 5 <0.002 0.002
Dimethyl sulfate Liquid 77-78-1 imm imm imm >160 0.02
Doxorubicin HCl (2 mg/ml) Liquid 25136-40-9 >240 >240 >240 5 <0.003 0.003
Ethane 1,2-diol Liquid 107-21-1 imm imm imm 6.6 0.002
Ethylene glycol Liquid 107-21-1 imm imm imm 6.6 0.002
Etoposide (Toposar®, Teva) (20 mg/ml, 33.2 % (v/v) Ethanol) Liquid 33419-42-0 >240 >240 >240 5 <0.01 <0.01
Fluorouracil, 5- (50 mg/ml) Liquid 51-21-8 imm imm >30 2 na 0.001
Formic acid (30%) Liquid 64-18-6 imm imm imm nm 0.001
Ganciclovir (3 mg/ml) Liquid 82410-32-0 >240 >240 >240 5 <0.005 0.005
Gemcitabine (38 mg/ml) Liquid 95058-81-4 imm >60 >240 5 <0.4 0.005
Glycerine Liquid 56-81-5 >240 >480 >480 6 0.03 0.01
Glycerol Liquid 56-81-5 >240 >480 >480 6 0.03 0.01
Glycol alcohol Liquid 107-21-1 imm imm imm 6.6 0.002
Hydrochloric acid (16%) Liquid 7647-01-0 imm imm imm na 0.05
Hydrochloric acid (32%) Liquid 7647-01-0 imm imm imm na 0.05
Hydrogen peroxide (10%) Liquid 7722-84-1 >10 >10 >480 6 <0.01 0.01
Hydrogen peroxide (30%) Liquid 7722-84-1 imm imm imm >0.11 0.04
Ifosfamide (50 mg/ml) Liquid 3778-73-2 >240 >240 >240 5 <0.009 0.009
Irinotecan (20 mg/ml) Liquid 100286-90-6 imm >240 >240 5 <0.1 0.0028
Mercuric II chloride (sat) Liquid 7487-94-7 >480 >480 >480 6 <0.01 0.01
Methotrexate (25 mg/ml, 0.1 N NaOH) Liquid 59-05-2 >240 >240 >240 5 <0.001 0.001
Mitomycin (0.5 mg/ml) Liquid 50-07-7 >240 >240 >240 5 <0.0009 0.0009
Nicotine (9 mg/ml) Liquid 54-11-5 >480 >480 >480 6 <0.08 0.08
Nitric acid (10%) Liquid 7697-37-2 >120 >240 >480 6 <0.005 0.005
Nitric acid (30%) Liquid 7697-37-2 imm imm imm 4.6 0.001
Oxaliplatin (5 mg/ml) Liquid 63121-00-6 imm imm imm na 0.006
Paclitaxel (Hospira) (6 mg/ml, 49.7 % (v/v) Ethanol) Liquid 33069-62-4 >240 >240 >240 5 <0.01 <0.01
Phosphoric acid (50%) Liquid 7664-38-2 >480 >480 >480 6 <0.05 0.05
Potassium chromate (sat) Liquid 7789-00-6 >480 >480 >480 6 <0.005 0.005
Potassium hydroxide (40%) Liquid 1310-58-3 imm imm >30 2 0.7 0.001
Propane -1,2,3-triol Liquid 56-81-5 >240 >480 >480 6 0.03 0.01
Sodium acetate (sat) Liquid 127-09-3 >480 >480 >480 6 <0.005 0.005
Sodium chloride (9 g/l) Liquid 7647-14-5 >240 >240 >240 5 <0.02 0.02
Sodium hydroxide (10%) Liquid 1310-73-2 >240 >480 >480 6 <0.005 0.005
Sodium hydroxide (40%) Liquid 1310-73-2 imm >30 >240 5 <0.005 0.005
Sodium hydroxide (50%) Liquid 1310-73-2 imm >30 >240 6 0.85 0.01
Sodium hydroxide (>95%, solid) Solid 1310-73-2 >480 >480 >480 6 <0.01 0.01
Sodium hypochlorite (10-15 % active chlorine) Liquid 7681-52-9 >240 >240 >480 6 <0.6 0.05
Sodium hypochlorite (5.25-6%) Liquid 7681-52-9 >480 >480 >480 6 <0.025 0.025
Sulfuric acid (18%) Liquid 7664-93-9 >240 >240 >480 6 <0.05 0.05
Sulfuric acid (30%) Liquid 7664-93-9 >10 >240 >240 5 <0.05 0.05
Sulfuric acid (50%) Liquid 7664-93-9 imm >30 >60 3 38 0.01
Sulfuric acid dimethyl ester Liquid 77-78-1 imm imm imm >160 0.02
Thiotepa (10 mg/ml) Liquid 52-24-4 imm imm imm na 0.001
Vincristine sulfate (1 mg/ml) Liquid 2068-78-2 >240 >240 >240 6 <0.001 0.001
Vinorelbine (0.1 mg/ml) Liquid 71486-22-1 >240 >240 >240 6 <0.0209 0.00209

PENETRATION AND REPELLENCY

A specific test method, EN ISO 6530, is used to measure the indexes of penetration, absorption and repellency of protective clothing material exposed to liquid chemicals. Results listed here reflect the penetration resistance and repellency of DuPont fabrics to 30% sulphuric acid and 10% sodium hydroxide.

Property Test Method Result EN
Repellency to Liquids, Sodium Hydroxide (10%) EN ISO 6530 >95 % 3 of 3 1
Repellency to Liquids, Sulphuric Acid (30%) EN ISO 6530 >95 % 3 of 3 1
Resistance to Penetration by Liquids, Sodium Hydroxide (10%) EN ISO 6530 <1 % 3 of 3 1
Resistance to Penetration by Liquids, Sulphuric Acid (30%) EN ISO 6530 <1 % 3 of 3 1
  •  According to EN 14325
  •  Larger than
  •  Smaller than

BIOLOGICAL BARRIER

Detailed information on the protective performance (resistance to penetration) of DuPont clothing when exposed to biologically contaminated aerosols, liquids and dusts as well as blood, body fluids and blood-borne pathogens. Sorted by relevant European standard.

Property Test Method Result EN
Resistance to Penetration by Biologically Contaminated Aerosols ISO/DIS 22611 Pass 1 of 3 2
Resistance to Penetration by Blood and Body Fluids using Synthetic Blood ISO 16603 Pass 3 of 6 2
Resistance to Penetration by Blood-borne Pathogens using Bacteriophage Phi-X174 ISO 16604 Procedure C No classification No classification 2
Resistance to Penetration by Contaminated Liquids EN ISO 22610 Pass 1 of 6 2
Resistance to Penetration by Contaminated Solid Particles ISO 22612 Pass 1 of 3 2
  •  According to EN 14126
  •  Larger than
  •  Smaller than

Warnings

  • The intended use for Tyvek® IsoClean Accessories, that are not CE certified or certified as PPE Category I, does not include applications that may cause very serious consequences such as irreversible damage to health or death. The user should make the risk assessment to determine the protection required.
  • The information provided herein corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as new knowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated; these data may not be valid for such material used in combination with any other materials or additives or in any process, unless expressly indicated otherwise. The data provided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you may need to conduct to determine for yourself the suitability of a specific material for your particular purposes. Since DuPont cannot anticipate all variations in actual end-use conditions DuPont makes no warranties and assumes no liability in connection with any use of this information. Nothing in this publication is to be considered as a license to operate under or a recommendation to infringe any patent rights.